Each model can have fresh air intake and a remote air diffuser can be connected to the unit.
Trane 4 pipe fan coil units.
The four pipe hvac system has a number of advantages over a two pipe system.
Trane blower coils factory packaged how you need it.
Four pipe systems have separate heating and cooling fan coil units and separate pipes for heating and cooling.
Unions are not available separately.
Horizontal blower coil bchd model unit sizes 12 18 24 36 54 72 90 mbh knockouts in all four corners for hanger rods 1 2 3 hp ecm motor standard direct drive up to 2 5 inches total static eliminates the difficulties with belts control box options.
This means that hot or chilled water is always available so the system can immediately change over from heating to cooling mode.
Unitrane harmony fan coil units are available as both cabinet and concealed versions with a wide array of options.
Hfcd series 50 hz.
2 features and benefi ts.
Unitrane fan coils are intended for single zone applications.
Building management controls mounted and configured with.
Chilled water fan coil unit model hfcf02 hfcf14 airfl ow range 200 2400m3 h hfcf hfxf vfcf.
The condensate pump integrated into the unit as standard is very quiet and has a maximum head of 650 mm.
2 pipe cooling only 2 pipe cooling heating or 4 pipe versions.
Trane chilled water fan coil units fwc 003 015 4 way cassette units fwh 002 006 high wall units december 2012 mc prc005 en product catalogue.
Water coils unitrane feu fcu fan coils are equipped with high performance water coils which are factory tested.
All vh units include two flexible stainless steel braided hoses and ball isolation valves per coil.
When you need it figure 1.
When ordered unions are installed at the water coil and are available on vav products and all fan coil units except vh.
Unions must be ordered on both coils of 4 pipe units.
In addition to the temperature.
Every unit can be supplied with 1 coil 2 pipe system and a possible electric heater or with 2 coils 4 pipe system.
These units have load capabilities of 200 to 1200 cfm.
Chilled water fan coil units for district cooling plant.
Accessible from below the unit.
G 4 pipe with 2 way valves lcd thermostat h 2 pipe with 2 way.
The airflow rate can.
4 pipe high capacity coil allowing higher cooling and heating capacity for the.
Fan coils provide cooling and heating and are available as two pipe with or without electric heat one hydronic circuit or fo ur pipe two hydronic circui ts.
Evident from the largest chiller to smallest fan coil trane s commitment to customer s needs for quality effi ciency and reliability is evident.